Model/Brand/Package
Category/Description
Inventory
Price
Data
-
Category: Classification of electronic componentsDescription: SC 28.x2 pro Series daily and weekly program permanent function (by date/holiday) manual permanent mode manual override automatic classification of reading switching time unlimited block programming fully automatic daylight saving time used time and pulse counter pulse function cycle function timer function advanced warning function channel button function ensures security through PIN code data key function # # # Note PC programming software package (stock number 453-934) and data key (stock number 453-930), can achieve program management and data backup, do not provide these two items, must be purchased separately # # # Remote programmable83631+$828.134810+$799.077450+$795.4452100+$791.8131150+$786.0016250+$780.9166500+$775.83151000+$770.0200
-
Category: Classification of electronic componentsDescription: SC28.13 pro 1 Channel Astro 35mm Astro program: automatically switches on and off based on sunrise and sunset, with a holiday switching capacity of 16A. It can be manually switched on or off permanently. Manual override is unlimited by number of days. Block programming is fully automatic, daylight saving time is used, and pulse counters are PIN encoded to provide security. Number # #46781+$1125.072310+$1114.844425+$1109.730450+$1104.6164100+$1099.5025150+$1094.3885250+$1089.2745500+$1084.1606
-
Category: Classification of electronic componentsDescription: Muller 1Channel DIN rail switch SC2811pro 24V ACDC, hourly measurement unit, 24V AC power supply91521+$704.192810+$679.484350+$676.3957100+$673.3072150+$668.3655250+$664.0415500+$659.71751000+$654.7758
-
Category: Classification of electronic componentsDescription: 24 Hour timer switch - VS 30/34 analog timer switch, used for DIN rail and wall mounting. These timer switches are available in two day models, with or without reserve function for daily or weekly programming. They are easy to program and come with dedicated setting keys. The slim 52.5mm model is easy to read and switch between program simulation displays (clock hands). The manual override switch permanently disconnects/automatically/permanently connects, making it easy to install with IP20 protection. Simulation93161+$441.728810+$430.205450+$421.3709100+$418.2980200+$415.9933500+$412.92041000+$410.99982000+$409.0793
-
Category: Classification of electronic componentsDescription: 50mm Diameter installation. Hole 46 x 46mm opening # # # Panel installation6732
-
Category: Classification of electronic componentsDescription: EQN/EQB Dynamic iron instrument, used for measuring AC current and voltage measurement accuracy: Class 1.5 front zero synchronous 100% overload range, with ammeter, used for starting bridge protection Class IP52 including pre installation, replaceable scale including installation frame, terminal cover 48 x 48 mm | 72 x 72 mm | 96 x 96 mm | measurement range | scale | used for converter ----------------------------------------------------------------------------------------------------------------------------------6 | 25/50 A communication | 0 → 25/50 A | n/a - | 202-827 | 392-8434 | 40/80 A communication | 0 → 40/80 A | n/a 202-473 | 201-896 | 392-9128 | 5/10 A communication | 0 → 50/100 A | 50/5 A 202-467 | 201-880 | 392-9718 | 5/10 A Communication | 0 → 100/200 A | 100/5 A 2022-445 | 202-782 | 392-9724 | 5/10 A Communication | 0 → 200/400 A | 200/5 A 204-378 | 202-776 | 392-8462 | 5/10 A Communication | 0 → 250/500 A | 250/5 A - | 201-903 | 392-8204 | 10 V Communication | 0 → 10 V | n/a - | - | 392-8305 | 30 V Communication | 0 → 30 V | n/a - | 202-798 | 392-8276 | 60 V Communication | 0 → 60 V | n/a 202-495 | 201-925 | 392-8529 | 250 Vac | 0 → 250 V | n/a 2022-489 | 201-919 | 392-8478 | 500 V AC | 0 → 500 V | n/a # # # Standard DIN 43700; EN 61010; VDE 0411; IEC 10101884
-
Category: Classification of electronic componentsDescription: 96 x 96 mm Permanent magnet dynamic coil instrument, used to measure current and voltage DQB Permanent magnet dynamic coil instrument measures direct current. If an instrument rectifier is used, the average value of pulsating DC can also be determined. Measurement accuracy: Level 1.5 (=maximum error of 1.5% in the final value). Front: 96 x 96 mm. For 92 x 92 mm standardized front panel cut (up to 6 mm thick), the front zero synchronization protection level is IP52. Pre installation, replaceable scale includes installation frame, terminal cover extension measurement range, shunt 60mV inventory number | measurement range | scale | for shunt -------------------------------------------------------------------------------| 60 V | 0 → 60 V | -392-8585 | 500 V | 0 → 500 V | -392-8428 | 20 mA | 0 → 100% | -392-9106 | 20 mA | 0 → 20 MA | -392-9134 | 0/4 → 20 mA | 0 → 100% | -392-8557 | 0/4 → 20 mA | 0 → 20 mA | -392-8620 | 15 A | 0 → 15 A | -392-8591 | 25 A | 0 → 25 A | -392-9702 | 60 mV | 0 → 25 A | 60 mV, 25 A 392-9140 | 60 mV | 0 → 40 A | 60 mV, 40 A 392-8636 | 60 mV | 0 → 100 A | 60 mV, 100 A 392-8507 | 60 → 0 → 60 mV | 25 → 0 → 25 A | 60 mV, 25 A # # # # Standard DIN 437 00; EN 61010; VDE 0411; IEC 1010 # # # Dynamic coil DC meter6196
-
Category: Classification of electronic componentsDescription: Counter: electromechanical; working time; Range:999999; -15÷60℃33041+$224.245410+$218.395550+$213.9106100+$212.3506200+$211.1807500+$209.62071000+$208.64572000+$207.6707
-
Category: Classification of electronic componentsDescription: LED LIGHT MODULE, 1 LED, WHITE, 1200LM5831
-
Category: timerDescription: MULLER BW40.18 240VAC Panel mounted timer, timer, 195.5 VAC, 264.5 VAC, 0 s, 99999 h51711+$183.467610+$178.681450+$175.0121100+$173.7358200+$172.7786500+$171.50231000+$170.70462000+$169.9069
-
Category: display deviceDescription: MULLER FRAME 55X55 Outer frame, hour counter798410+$8.0808100+$7.6768500+$7.40741000+$7.39392000+$7.34015000+$7.27277500+$7.218810000+$7.1919
-
Category: display deviceDescription: MULLER MASK 72X72 Outer frame, used for hour counter50345+$15.261550+$14.6093200+$14.2440500+$14.15271000+$14.06142500+$13.95715000+$13.89197500+$13.8266
-
Category: Classification of electronic componentsDescription: SC 08.11 pro,Single channel manual permanent mode, manual override permanent function (by date/holiday), automatic classification of reading switching time, unlimited block programming, used time and pulse counter. Pulse function ensures security through PIN code. PC programming module (453-934) and data key (453-930) are provided separately. # # Remote programmable14691+$846.823910+$817.110850+$813.3967100+$809.6825150+$803.7399250+$798.5401500+$793.34031000+$787.3977
-
Category: Classification of electronic componentsDescription: EQN/EQB Dynamic iron instrument, used for measuring AC current and voltage measurement accuracy: Class 1.5 front zero synchronous 100% overload range, with ammeter, used for starting bridge protection Class IP52 including pre installation, replaceable scale including installation frame, terminal cover 48 x 48 mm | 72 x 72 mm | 96 x 96 mm | measurement range | scale | used for converter ----------------------------------------------------------------------------------------------------------------------------------6 | 25/50 A communication | 0 → 25/50 A | n/a - | 202-827 | 392-8434 | 40/80 A communication | 0 → 40/80 A | n/a 202-473 | 201-896 | 392-9128 | 5/10 A communication | 0 → 50/100 A | 50/5 A 202-467 | 201-880 | 392-9718 | 5/10 A Communication | 0 → 100/200 A | 100/5 A 2022-445 | 202-782 | 392-9724 | 5/10 A Communication | 0 → 200/400 A | 200/5 A 204-378 | 202-776 | 392-8462 | 5/10 A Communication | 0 → 250/500 A | 250/5 A - | 201-903 | 392-8204 | 10 V Communication | 0 → 10 V | n/a - | - | 392-8305 | 30 V Communication | 0 → 30 V | n/a - | 202-798 | 392-8276 | 60 V Communication | 0 → 60 V | n/a 202-495 | 201-925 | 392-8529 | 250 Vac | 0 → 250 V | n/a 2022-489 | 201-919 | 392-8478 | 500 V AC | 0 → 500 V | n/a # # # Standard DIN 43700; EN 61010; VDE 0411; IEC 10107542
-
Category: Classification of electronic componentsDescription: 13mm、3.5 The LED voltage/current panel meter can be electrically connected through screw terminal blocks, and can be installed by interlocking or fixed with screws. It can be configured with plug-in links and pre-set settings for automatic zero adjustment, automatic polarity conversion, and zero offset; Automatic zeroing or (if selected), adjustable to 25% of the range, display brightness and decimal point position adjustable, zero position and range with 3 readings per second, sampling rate accuracy: dependent on 100 μ V/1 μ A range, temperature stability: 50ppm/° C, input impedance - current range | | | voltage range 1-10mA | 10-100mA | 100-300mA | 0.2-300V 202 Ω | 20 Ω | 2 Ω | 1.058 M Ω # # # LED/LCD digital voltmeter and ammeter, all instruments have a working range of 0 to 50 ° C. Size - Stock Number | DIN (German Industrial Standard) | Height (mm) | Width (mm) | Depth (mm) | Panel Thickness (mm) | Panel Rear Depth (mm) | Panel Cut (mm) 269-007 | 1/2 | 24 | 96 | 80 | Maximum Value 7, 4 for biting | - | 92 x 22.5 269-013 | 1 | 48 | 96 | 150 | Maximum Value 7, 4 for biting | - | 92 x 45 260-189 | 1 | 48 | 96 | 150 | Maximum Value 7, 4 for biting | - | 92 x 45 260-202 | 1/2 | 24 | 96 | 150 | Maximum Value 7, 4 for biting | - | 92 x 22.5 260-218 | 1 | 48 | 96 | 150 | Maximum value 7, 4 for biting | - | 92 x 45 269-029 | 1 | 48 | 96 | 150 | Maximum value 7, 4 for biting | - | 92 x 45 260-195 | 1 | 48 | 96 | 150 | Maximum value 7, 4 for biting | - | 92 x 45 260-224 | 1 | 48 | 96 | 150 | Maximum value 7, 4 for biting | - | 92 x 45 186-2679 | - | 34.5 | 64.5 | 5.5 | 3 | 2 | 38 x 1831891+$1787.808010+$1771.555225+$1763.428850+$1755.3024100+$1747.1760150+$1739.0496250+$1730.9232500+$1722.7968
-
Category: Classification of electronic componentsDescription: EQN/EQB Dynamic iron instrument, used for measuring AC current and voltage measurement accuracy: Class 1.5 front zero synchronous 100% overload range, with ammeter, used for starting bridge protection Class IP52 including pre installation, replaceable scale including installation frame, terminal cover 48 x 48 mm | 72 x 72 mm | 96 x 96 mm | measurement range | scale | used for converter ----------------------------------------------------------------------------------------------------------------------------------6 | 25/50 A communication | 0 → 25/50 A | n/a - | 202-827 | 392-8434 | 40/80 A communication | 0 → 40/80 A | n/a 202-473 | 201-896 | 392-9128 | 5/10 A communication | 0 → 50/100 A | 50/5 A 202-467 | 201-880 | 392-9718 | 5/10 A Communication | 0 → 100/200 A | 100/5 A 2022-445 | 202-782 | 392-9724 | 5/10 A Communication | 0 → 200/400 A | 200/5 A 204-378 | 202-776 | 392-8462 | 5/10 A Communication | 0 → 250/500 A | 250/5 A - | 201-903 | 392-8204 | 10 V Communication | 0 → 10 V | n/a - | - | 392-8305 | 30 V Communication | 0 → 30 V | n/a - | 202-798 | 392-8276 | 60 V Communication | 0 → 60 V | n/a 202-495 | 201-925 | 392-8529 | 250 Vac | 0 → 250 V | n/a 2022-489 | 201-919 | 392-8478 | 500 V AC | 0 → 500 V | n/a # # # Standard DIN 43700; EN 61010; VDE 0411; IEC 10109502
-
Category: Classification of electronic componentsDescription: Suitable shunts, 60 mV Calibrated shunts are used for measuring higher currents with DQN moving-coil instruments Connected in parallel with measuring instrument 25 A version pre-installed on insulating base Screw connection Voltage drop: | 60 mV ---|--- for display power consumption: | 5 mA (e.g. display DQN) Accuracy class: | 0.5 Weight: | 0.1 kg ### Dynamic coil DC meter9290
-
Category: Classification of electronic componentsDescription: 13 mm,5 Position LED Indicator/Controller - DPM 48/4000MFE1 can be programmed for microprocessor-based devices to measure voltage, current, or temperature. An external shunt can be used to measure higher input current signals and can be scaled, combined, or recorded at a sampling rate of 4 readings per second. Function configuration can be done using front panel buttons or through a remote PC. Electrical connection is provided through screw terminal blocks. Software configuration package, interface wires, and a 9 to 25 way D-type adapter (stock number 218-289) are provided. Zero offset is achieved by mathematically combining signals from similar devices using two or more instruments. Digital display filters for minimum/maximum/hold memory and data recording memory are available, with time base isolation, analog recorder output, wide range, universal switch mode, PSU display, hold device size: high. 48 x width 96 x 143mm deep panel rear depth: 151mm panel notch: 92 x 45.5mm panel thickness: 22mm # # # DPM 48/4000MFE1- Other features 25 points user definable scale/linearization true RMS AC measurement five display and data recording status indicators power supply | 24 to 48V DC ± 20%, 24 to 230V AC+15/-20%, maximum 4W --- | working temperature | 0 to 50 ° C * * * signal processing * * | linear scale | bias y=ax+b non-linear scale | square, root, sin, cos, tan, log combined signal |+, - x、 /Average, A/B%, B/A% data recording | 160 readings, maximum sampling interval of 18 hours continuous or triggered set points | 4 set points with adjustable threshold, hysteresis, delay and reset | Delay and reset AC/DC conversion | 10/20 readings per second, ± 40k words * * Suitable for DPM 48/40000MFE1 output specifications * * | Analog output | 4-20mA or -20 to+20mA alarm mode | Four relays, flashing display relay output | 30V DC/250V AC 1A serial interface | RS-485 addressable, 9600 baud rate (8-e-1), 9-pin connector # # # Comes with mounting ring # # # LEDPt100/thermocouple display7253
-
Category: Classification of electronic componentsDescription: EQN/EQB Dynamic iron instrument, used for measuring AC current and voltage measurement accuracy: Class 1.5 front zero synchronous 100% overload range, with ammeter, used for starting bridge protection Class IP52 including pre installation, replaceable scale including installation frame, terminal cover 48 x 48 mm | 72 x 72 mm | 96 x 96 mm | measurement range | scale | used for converter ----------------------------------------------------------------------------------------------------------------------------------6 | 25/50 A communication | 0 → 25/50 A | n/a - | 202-827 | 392-8434 | 40/80 A communication | 0 → 40/80 A | n/a 202-473 | 201-896 | 392-9128 | 5/10 A communication | 0 → 50/100 A | 50/5 A 202-467 | 201-880 | 392-9718 | 5/10 A Communication | 0 → 100/200 A | 100/5 A 2022-445 | 202-782 | 392-9724 | 5/10 A Communication | 0 → 200/400 A | 200/5 A 204-378 | 202-776 | 392-8462 | 5/10 A Communication | 0 → 250/500 A | 250/5 A - | 201-903 | 392-8204 | 10 V Communication | 0 → 10 V | n/a - | - | 392-8305 | 30 V Communication | 0 → 30 V | n/a - | 202-798 | 392-8276 | 60 V Communication | 0 → 60 V | n/a 202-495 | 201-925 | 392-8529 | 250 Vac | 0 → 250 V | n/a 2022-489 | 201-919 | 392-8478 | 500 V AC | 0 → 500 V | n/a # # # Standard DIN 43700; EN 61010; VDE 0411; IEC 10103080
-
Category: Classification of electronic componentsDescription: Paladin 923500 The dusk switch simulation dusk switch includes sensors for wall mounted DIN rail installation with 17.5mm two adjustment ranges of 1-100/500-1000 Lux. It has a delay of approximately 8 seconds when opened and a delay of approximately 40 seconds when closed. The closing value is approximately 1.4 times the opening value and zero crossing switching is suitable for relay energy-saving switching IP54 (sensor), IP20 (control device) protection # # # photoelectric88501+$489.571110+$476.799750+$467.0083100+$463.6025200+$461.0483500+$457.64261000+$455.51402000+$453.3854
-
Category: Classification of electronic componentsDescription: TIME SWITCH, DIGITAL; Contact Style: 1CO; Contact Current Max: 16A; Controller Output: Digital; Time Range: 24H / 7da...3246
-
Category: Classification of electronic componentsDescription: DPM24 / 96-2000S indicators DIN format panel meter with 7 segment 3 1/2 digit LED display. Wide range of voltage and direct current measurements that can be defined by the user using a simple jumper. Zero shift within limit of 25% of the range (e.g.: 4 → 20 mA Indication of range being exceeded. Adjustable decimal point and brightness. **Standard: IEC 1010** Supply voltage: | ---|--- \- S/5 version: | 5 Vdc ±5% \- S24 version: | 24 Vdc ±15% \- S/230 version: | 230 Vac +10% / -15% Measurement range: | 0.2 → 300 Vdc / 1 → 200 mA Resolution: | 2000 points Sampling: | 3/s Integration time: | 80 ms Height of digits: | 13 mm Dimensions (mm): | 96 x 24 x 72 Panel cut-out (mm): | 22.2 x 92 Protection index: | IP 54 front panel Connection: | screw terminals Operating temperature: | 0°C to +50°C ### LED/LCD All digital voltmeters and ammeters have a working range of 0 to 50 ° C. Size - Stock Number | DIN (German Industrial Standard) | Height (mm) | Width (mm) | Depth (mm) | Panel Thickness (mm) | Panel Rear Depth (mm) | Panel Cut (mm) 269-007 | 1/2 | 24 | 96 | 80 | Maximum Value 7, 4 for biting | - | 92 x 22.5 269-013 | 1 | 48 | 96 | 150 | Maximum Value 7, 4 for biting | - | 92 x 45 260-189 | 1 | 48 | 96 | 150 | Maximum Value 7, 4 for biting | - | 92 x 45 260-202 | 1/2 | 24 | 96 | 150 | Maximum Value 7, 4 for biting | - | 92 x 22.5 260-218 | 1 | 48 | 96 | 150 | Maximum value 7, 4 for biting | - | 92 x 45 269-029 | 1 | 48 | 96 | 150 | Maximum value 7, 4 for biting | - | 92 x 45 260-195 | 1 | 48 | 96 | 150 | Maximum value 7, 4 for biting | - | 92 x 45 260-224 | 1 | 48 | 96 | 150 | Maximum value 7, 4 for biting | - | 92 x 45 186-2679 | - | 34.5 | 64.5 | 5.5 | 3 | 2 | 38 x 182867
-
Category: Classification of electronic componentsDescription: DPM24 / 96-2000S indicators DIN format panel meter with 7 segment 3 1/2 digit LED display. Wide range of voltage and direct current measurements that can be defined by the user using a simple jumper. Zero shift within limit of 25% of the range (e.g.: 4 → 20 mA Indication of range being exceeded. Adjustable decimal point and brightness. **Standard: IEC 1010** Supply voltage: | ---|--- \- S/5 version: | 5 Vdc ±5% \- S24 version: | 24 Vdc ±15% \- S/230 version: | 230 Vac +10% / -15% Measurement range: | 0.2 → 300 Vdc / 1 → 200 mA Resolution: | 2000 points Sampling: | 3/s Integration time: | 80 ms Height of digits: | 13 mm Dimensions (mm): | 96 x 24 x 72 Panel cut-out (mm): | 22.2 x 92 Protection index: | IP 54 front panel Connection: | screw terminals Operating temperature: | 0°C to +50°C ### LED/LCD All digital voltmeters and ammeters have a working range of 0 to 50 ° C. Size - Stock Number | DIN (German Industrial Standard) | Height (mm) | Width (mm) | Depth (mm) | Panel Thickness (mm) | Panel Rear Depth (mm) | Panel Cut (mm) 269-007 | 1/2 | 24 | 96 | 80 | Maximum Value 7, 4 for biting | - | 92 x 22.5 269-013 | 1 | 48 | 96 | 150 | Maximum Value 7, 4 for biting | - | 92 x 45 260-189 | 1 | 48 | 96 | 150 | Maximum Value 7, 4 for biting | - | 92 x 45 260-202 | 1/2 | 24 | 96 | 150 | Maximum Value 7, 4 for biting | - | 92 x 22.5 260-218 | 1 | 48 | 96 | 150 | Maximum value 7, 4 for biting | - | 92 x 45 269-029 | 1 | 48 | 96 | 150 | Maximum value 7, 4 for biting | - | 92 x 45 260-195 | 1 | 48 | 96 | 150 | Maximum value 7, 4 for biting | - | 92 x 45 260-224 | 1 | 48 | 96 | 150 | Maximum value 7, 4 for biting | - | 92 x 45 186-2679 | - | 34.5 | 64.5 | 5.5 | 3 | 2 | 38 x 188065
-
Category: Classification of electronic componentsDescription: EQN/EQB Dynamic iron instrument, used for measuring AC current and voltage measurement accuracy: Class 1.5 front zero synchronous 100% overload range, with ammeter, used for starting bridge protection Class IP52 including pre installation, replaceable scale including installation frame, terminal cover 48 x 48 mm | 72 x 72 mm | 96 x 96 mm | measurement range | scale | used for converter ----------------------------------------------------------------------------------------------------------------------------------6 | 25/50 A communication | 0 → 25/50 A | n/a - | 202-827 | 392-8434 | 40/80 A communication | 0 → 40/80 A | n/a 202-473 | 201-896 | 392-9128 | 5/10 A communication | 0 → 50/100 A | 50/5 A 202-467 | 201-880 | 392-9718 | 5/10 A Communication | 0 → 100/200 A | 100/5 A 2022-445 | 202-782 | 392-9724 | 5/10 A Communication | 0 → 200/400 A | 200/5 A 204-378 | 202-776 | 392-8462 | 5/10 A Communication | 0 → 250/500 A | 250/5 A - | 201-903 | 392-8204 | 10 V Communication | 0 → 10 V | n/a - | - | 392-8305 | 30 V Communication | 0 → 30 V | n/a - | 202-798 | 392-8276 | 60 V Communication | 0 → 60 V | n/a 202-495 | 201-925 | 392-8529 | 250 Vac | 0 → 250 V | n/a 2022-489 | 201-919 | 392-8478 | 500 V AC | 0 → 500 V | n/a # # # Standard DIN 43700; EN 61010; VDE 0411; IEC 10105785
-
Category: Classification of electronic componentsDescription: Muller 1Channel DIN rail switch VS3018 230V 50-60Hz, hourly measurement unit, 230V power supply33611+$288.214210+$280.695550+$274.9312100+$272.9263200+$271.4225500+$269.41761000+$268.16452000+$266.9114
